The ASPTC is a white, elongated radiation shield that reduces solar loading on a thermocouple by drawing air across the measurement junction with a fan. The radiation shield also protects the sensor, increasing its durability.
Typically, one ASPTC is mounted to each sensor arm in a Bowen ratio system. One ASPTC can either replace, or be measured in addition to, TCBR thermocouples. In a standard configuration, lead lengths of 4.6m (15 feet) are recommended for both signal and power cables.
Features
- Uses fine wire thermocouple for highly accurate air temperature measurements
- Includes aspirated radiation shield
- Solar loading on thermocouple reduced by drawing air across the measurement junction with a high-powered fan
- Intake velocity is 5.5 m/sec
- Fan requires 12 Vdc power supply
- Fan average active current drain is 142 mA
Specifications
- Weight: 860 g (1.9 lbs); 700g (1.6 lb) without cable
- Length: 53.3 cm (21")
- Height: 14.7 cm (5.8")
- Large diameter: 5.8 cm (2.3")
- Small diameter: 4.6 cm (1.8")
- Power cable diameter: 0.5 cm (0.2")
- Signal cable diameter: 0.3 cm (0.1")