The CR800 provides a lower-cost datalogger alternative for measurements of a limited number of sensors, yet can be used with most of our telecommunication devices such as cellular telephones, UHF/VHF RF modems, and satellite transceivers. The CR800 datalogger uses external power supplies and keyboard displays..
Features
The CR800 provides a lower-cost datalogger alternative for measurements of a limited number of sensors, yet can be used with most of our telecommunication devices such as cellular telephones, UHF/VHF RF modems, and satellite transceivers. The CR800 datalogger uses external power supplies and keyboard displays.
Specifications
- Current Drain: ~0.6 mA (sleep mode), 1 to 16 mA (w/o RS-232 communications), 17 to 28 mA (w/RS-232 communications)
- A/D Bits: 13
- Scan Rate: 100 Hz
- Analog Inputs: 6 single-ended (3 differential), individually configured
- Analog Voltage Range: ±5000 mV
- Analog Voltage Accuracy: ±(0.06% of reading + offset), 0° to 40°C
- Measurement Resolution: 0.33 µV
- Switched Excitations: 2 voltage
- Pulse Counters: 2
- Control/Digital Ports: 4
- Memory: 2 MB Flash (operating system), 4 MB (CPU usage, program storage, and data storage)
- Communication Ports: 1 RS-232, 1 CS I/O
- Protocols Supported: PakBus, Modbus, DNP3, FTP, HTTP, XML, POP3, SMTP, Telnet, NTCIP, NTP, SDI-12, SDM
- Warranty: 3 years